Hybrid & EV
P0AA6
Hybrid/EV Battery Voltage System Isolation Fault
Generic (SAE J2012) · last verified 2026-11-27
What it means
The vehicle's computer detected an electrical leak where high-voltage electricity is touching the metal frame of the car, which poses a severe shock hazard.
Safety implications
This is a severe safety hazard. The vehicle is unsafe to drive because of the risk of electric shock, and all high-voltage work must be performed by a qualified hybrid technician.
Possible causes
- ·Damaged high-voltage cable insulation
- ·Moisture intrusion in high-voltage components
- ·Defective inverter
- ·Damaged battery pack housing
Common symptoms
Recommended diagnostic tests
- 01Check insulation resistance with a megohmmeter
- 02Inspect high-voltage wiring for physical damage
- 03Scan for low-voltage sensor codes
- 04Inspect inverter cooling system for leaks
Related components
Related codes
Reference and verification
Generic OBD-II diagnostic trouble code definitions (SAE J2012)
SAE International · retrieved 2026-11-27
Limitation: Generic definition only. Manufacturer-specific meaning may differ.
- Generated from the standard generic definition set, checked for a valid code pattern and complete fields before publishing. Review in Admin > Codes.
Want this narrowed to your vehicle?
WrenchClue researches your year, make, model and engine for causes, tests and reference pricing.
Community experiences
These are experiences shared by other owners about this exact issue. They are not verified diagnostic guidance and they may not apply to your vehicle.